SONEX® Pyramid Panels Technical Specifications
Physical Data — willtec®
| Material |
Open-cell melamine-based foam |
| Density |
0.5 to 0.7 lbs./cubic ft. (ASTM D3574-77) |
| Long-Term Service Temperature |
302 degrees F |
| Fire Resistance |
Class 1 per ASTM E 84 (all finishes) Meets UL 1715 (willtec natural) |
| Flame Spread per ASTM E 84 |
Natural: 5 Painted: 10 |
| Smoke Density per ASTM E 84 |
Natural: 50 Painted: 10 |
| Microbial Growth |
Passes UL 181, section 11 |
| Fungus Resistance |
Rating 0 per ASTM G21 |
| Finishes |
Natural White or Grey, painted |
Sound Absorption
| Finish |
Thickness |
Coefficients per ASTM C423-90a
|
| |
|
125Hz
|
250Hz
|
500Hz
|
1kHz
|
2kHz
|
4kHz
|
NRC
|
Mounting Type
|
| Natural White or Grey |
2" 3" 4" |
0.07 0.09 0.18 |
0.25 0.37 0.44 |
0.6 0.81 0.96 |
0.94 1.01 1.14 |
0.97 1.03 1.18 |
1.08 1.07 1.19 |
0.7 0.8 0.95 |
B B B |
Painted (Charcoal, Beige, Brown, Blue, Light-Grey) |
2", 3", 4" |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
B |
Installation Information
- Make sure both the panels and the surface to which the panels are being applied are free of dust and dirt. If adhering to a metal surface, use a degreaser.
- Apply a line of adhesive around the perimeter of the panel approximately 1" from the edge.
- Apply a line of adhesive from opposite corners through the center of the panel, creating an "X".
- Press panel into place and hold for 5 seconds. Then pull panel away to allow adhesive to become tacky. Last, press the panel back into position and hold again for 5 seconds.
- Wear clean cotton/canvas gloves for installation.
- Use a sharp razor or fixed blade-knife and a metal straightedge to cut panels. For best results, cut panels on flat side.
- Overhead installations may require additional adhesive and mechanical support to ensure a strong enough bond.
To find out more about SONEX Pyramid Panels, explore the "Related Links" and "Ralated Downloads" area, located on the right side of this page.
|