Flammability
willtec meets the following regulations for flame spread, smoke density, and fuel contribution:
ASTM E-84, Steiner Tunnel Test willtec:
Natural: Class 1 fire-rated
- Flame spread: 5
- Smoke Density: 50
Painted: Class 1 fire-rated
- Flame spread: 10
- Smoke density: 10
Hypalon-coated: Class 1 fire-rated
- Flame spread: 25
- Smoke density: 65
Colortec foam: Class 1 fire-rated
- Flame spread: 5
- Smoke density: 90
UL 1715, Corner Burn Test
UL code 94, electronics
- HBF: Passes
- HF1: Passes
- VO: Passes
|
pinta products made with willtec foam:
(please see individual project sheets for more information)
*SQUARELINE ceiling tiles use a slightly different formulation of willtec, called willtec FM, which is not colortec.
Miscellaneous Tests: willtec meets a variety of other tests to show that it is suitable for a wide variety of installations.
Smoke Toxicity, New York City willtec: DOS# 0-500-970317-4001
Boeing DSS 9739, toxic gas generation willtec: Passes
UL181, microbial growth willtec: Passes
TM G21, fungus resistance willtec: Passes
|